20,000 Watt Amplifier with 4 Flexible Output Channels on SpeakON Connectors, Lake Digital Signal Processing and Digital Audio Networking for Touring Applications
PLM 20K44 SP
The PLM 20K44 is the natural successor of the proven, road tested, and trusted LAB GRUPPEN touring foundation exemplified by the iconic PLM 20000Q. Now offering an extended 4-in, 4-out configuration together with twice the processing power via the latest version 6.3 Lake Controller release, plus industry-standard Dante® networking, the PLM 20K44 sets the benchmark for Powered Loudspeaker Management Systems.
The PLM 20K44 combines four channels of extremely powerful amplification with unrivalled signal processing and audio management. At the core of the system concept is the total integration of all devices – including networking, audio I/O, signal processing, amplifiers, power supply and connected mains supply – allowing complete control and monitoring of the entire platform, resulting in unique operational benefits.
The Power of LAKE Processing
The PLM 20K44 features the legendary power of exclusive LAKE Processing algorithms, incorporating four full-featured LAKE modules with four discrete channels of audio throughput input to output. Audio signals are selectable from four channels of analog (with Iso-Float ground isolation), four channels via AES3 digital inputs and eight dual redundant Dante networked digital inputs. Input signals are individually selectable for each channel, with programmable failover to a lower prioritized input.
The full-featured, on-board LAKE Processor includes group control with Raised Cosine MESA EQ asymmetric filters to match the responses of any loudspeaker system. LimiterMax peak and RMS limiters set the industry standard for loudspeaker protection and sonic transparency.
The included LAKE Controller software provides a unified interface for control of Lake functions and for comprehensive monitoring of both amplifier status and connected loudspeaker loads. Optimized for a wireless tablet PC, LAKE Controller is easy and intuitive to operate, with the “feel” of real-time analog faders and controls. Lake Controller also features seamless integration with third party, real-time sound system measurement, optimization, and control software packages. Users can measure spectrum and transfer function and adjust system EQ at the same time, using the same user interface.
LAKE Processing offers classical crossovers (selectable up to 48 dB per octave) as well as linear-phase crossovers capable of slopes exceeding 180 dB per octave for greater control to limit lobing and off-axis cancellation.
Allocate Power Where It Is Needed
RPM Provides ultimate flexibility of power output allocation across channels to match specific load requirements, enabling more efficient use of amplifier inventory
General
Processing / Network |
Lake / Dante |
Number of amplifier channels |
4 |
Total burst power all channels (share among channels with RPM) |
20000 W |
Max output power (all channels driven)1
2 ohms |
4400 W |
2.67 ohms |
5000 W |
4 ohms |
4400 W |
8 ohms |
2300 W |
16 ohms |
1150 W |
Hi-Z 70 V |
3300 W |
Hi-Z 100 V |
4700 W |
Max output power single channel1
2 ohms |
4400 W |
2.67 ohms |
5900 W |
4 ohms |
4600 W |
8 ohms |
2300 W |
16 ohms |
1150 W |
Hi-Z 70 V |
3300 W |
Hi-Z 100 V |
4700 W |
Amplifier output modules (all models, all channels)
Peak output voltage |
194 V |
Max. output current |
67 A |
Rational Power Management (RPM) |
Regardless of model, any channel has potential to deliver the max single channel output power |
Default voltage limitation (can be lifted with RPM configuration) |
194 V |
Protection features |
Current Average Limiter (CAL), Very High Frequency Protection (VHF), Direct Current Protection (DC), Short Circuit Protection, Current-Clip Limiter, Voltage Clip Limiter, Temperature protection |
Audio Performance (Amplifier platform with digital input)
THD + N 20 Hz – 20 kHz for 1 W |
< 0.05 % |
THD + N at 1 kHz and 1 dB below clipping |
< 0.04 % |
Dynamic range |
> 114 dB |
Channel separation (Crosstalk) at 1 kHz |
> 70 dB |
Frequency response (1 W into 8 Ohm, 20 Hz – 20 kHz) |
+/- 0.05 dB |
Internal Sample Rate / Data path |
48 / 96 kHz / 32 bit floating point |
Product propagation delay AES 96 kHz / analog input |
1.61 / 1.68 ms |
Lake processing
Loudspeaker processing |
Up to 4 modules of Classic/linear-phase/FIR crossover, EQ, delay, LimiterMax™ – peak and RMS limiters |
System tuning |
Group control with Raised Cosine™ MESA EG™ asymmetric filters |
Input redundancy / Matrix |
Automatic 4 level input redundancy / 4 input mixers |
System integration |
Comprehensive 3rd party protocol over UDP Ethernet |
Measurement & Analysis
Pilot tone generation and analysis |
Yes |
Load impedance analysis |
Yes |
Real Time Analyzer (RTA), 3rd party integration |
Yes |
Dante Audio Network
Dante I/O |
8 x 8 |
Network topology / redundancy |
Flexible topology / Supports daisy-chained and Dual redundant networks |
Sample Rates / Transport |
48, 96 kHz / Uni + Multicast |
Network latency |
0.25, 0.5, 1.0, 2.0, 5.0 ms |
Device presets
Local memory locations for the settings of the product |
100 |
AES Inputs
Inputs |
4 AES inputs |
Supported sample rates / resolution |
44.1, 48, 88.2, 96, 176.4, 192 kHz / up to 24 bits |
Sample rate conversion THD+N 20 Hz – 20 kHz unweighted |
0.0000003 |
Analog Inputs
Inputs |
4 high quality inputs with Iso-Float ground isolation |
Maximum input / digital reference |
+26 dBu / +21 dBu |
Sampling rate / Resolution |
96 kHz / 24 bit |
Input impedance balanced / unbalanced |
20 / 10 kOhm |
THD+N (typical at 1 kHz unweighted) |
0.0000022 |
THD+N (typical at 20 Hz and 20 kHz unweighted) |
0.0000033 |
Limiters
Adjustable Inter-Sample Voltage Peak Limiter (ISVPL) |
17.8 – 194 V, step size 0.1 V |
Current Peak Limiter < 300 ms |
67 A peak |
Current Average Limiter (CAL) > 300 ms |
33 Arms |
MaxRMS (rms voltage limiter) |
Yes |
MaxPeak (peak voltage limiter) |
Yes |
Gain
Amplifier gain |
22 – 44 dB, step size 0.1 dB |
Output attenuator |
-Inf to 0 dB, step size 0.25 dB |
Back panel Interface
Analog, 2-channel I/O (input + link) |
4 x 3-pin XLR, electronically balanced |
AES / EBU / I/O (input + link) |
2 x 3-pin XLR |
Output connectors |
Neutrik speakON (1 x NLT8, 2 x NLT4) or 4 Binding Posts (pairs) |
Auto 10/100, Auto Uplink |
2 x RJ45 etherCON |
Control and monitoring interface |
Via Ethernet for Lake Controller software, or DLM (the 3rd party protocol) |
Detachable mains cord |
Neutrik PowerCon rated at 250V/32A |
Cooling |
Three fans, front-rear airflow, temperature controlled speed |
Front-panel user interface
Display |
2.5 inch, black / white, daylight readable LCD |
Fault/Warning/Limit/Clip indicators |
RGB LEDs and detailed fault description on display |
Mute and soft function buttons |
8 provided |
Standby Power button |
On/Standby |
Mute Enable button |
Enables muting of outputs and inputs via soft-button keypad |
Meter button |
Toggles through meter views |
Menu button |
Provides a menu driven interface for full function front panel control |
Rotary Encoder |
Yes |
Exit Button |
Provides a “back” function |
Mains Power
Nominal voltage |
100 – 240 Volt AC 45 – 66 Hz |
Operating voltage |
70-265 V AC |
Mains wall plug |
NEMA L5-30 „Twist lock“ 125 V / 30 A, and CEE 7/7 „Schuko“ 230 V / 16 A |
Power supply features
Soft start / Inrush power |
Yes/ Max 8 Ampere |
Power Factor Correction (PFC) |
0.98 |
Regulated switch mode power supply (R.SMPS) |
Yes |
Breaker Emulation Limiter (BEL) |
Configurable current threshold and breaker profile |
BEL max current threshold |
32 A |
Power Average Limiter (PAL) |
Yes |
Under Voltage Limiter (UVL) |
Yes |
Mains undervoltage and overvoltage protection and mains glitch tolerance |
Yes |
Dimensions
Rack rail to rear panel |
W: 483 mm (19″), H: 88 mm (2 U), D: 424 mm (16″) |
Overall depth front-rear support |
D: 498 mm (19.6″) |
Weight